C Tec Cfp Fire Panel User Manual

Posted on by

CFP702-4

Nov 29, 2013  How to disable/enable zones and other functions on a CFP fire alarm panel. The auxiliary output or output delays on a CFP conventional fire alarm panel. C-TEC's new Hush-Pro fire alarm. CFP 2-8 Zone Fire Panels. FP/MFP 1-28 Zone Fire Panels. EP203 Automatic Extinguisher Panels. Programming software and 3D BIM models, our new Support Hub aims to give you fast access to all things C-TEC. Simply click on the boxes below. Discover how C-TEC's 'hands on' training sessions can help you get ahead of the competition. View and Download XFP NETWORKABLE ANALOGUE ADDRESSABLE FIRE ALARM CONTROL PANEL user manual online. NETWORKABLE ANALOGUE ADDRESSABLE FIRE ALARM CONTROL PANEL Control Panel pdf manual download. KEY FEATURES This 1 or 2 loop (dependent on the model purchased) 32 zone analogue addressable fire alarm panel offers the following features:. Full compliance with EN54 parts 2 and 4, including EN54-2 Clauses 7.8 - Output to fire alarm devices, 8.3 - Fault Signals from points and 9.5 - Disablement of addressable points. The four zone fire CFP AlarmSense alarm panel from C-Tec can have a maximum of 25 detectors and manual call points connected to each zone. Conventional fire alarm panels typically use four wires to separate the detection device and sounder circuits; however the CFP AlarmSense has a two wire design, meaning that all components can be fitted across the same pair of supply wires.

C-Tec

C-Tec CFP 2-8 Zone Conventional Fire Panel

C-TEC's award-winning CFP conventional fire panel is LPCB certified to EN54 parts 2 and 4 and offers an array of user and installer-friendly features at a very competitive price.

Supplied in an attractive flush or surface mountable plastic enclosure, 2, 4 and 8 zone versions are available, each featuring four conventional sounder circuits, class change and alert inputs, on-board fire and fault relays and combined keypad/keyswitch entry.

A wide range of engineering functions are also provided including selectable zone delays, coincidence and non-latching zone facilities. Comprehensive test and fault finding facilities are also provided.

Features

  • LPCB certified to EN54 Parts 2 and 4
  • Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry to access level 2
  • 2, 4 or 8 zone circuits (dependent on model purchased)
  • Four conventional sounder circuits
  • Integral 1.5A EN54-4/A2 compliant switch mode PSU
  • Wide range of engineering functions including zone test, coincidence*, zone delay and non-latching zones*
  • Two on-board relays (Fire and Fault)
  • Two open-collector outputs (Remote and Reset)
  • ‘Class change’ and alert inputs
  • Installer-friendly design accommodates easy first fix and straightforward maintenance
  • Attractive flush or surface mountable plastic lid and enclosure - no bezel required
  • Low 25mA quiescent current
  • Multiple indicators
  • End of line units included (one per zone)
  • Ancillary system expansion connections provided for up to eight two-wire repeaters (one CFP761 network driver card required per system) and optional CFP relay boards
  • Space for two x 12V 3.3Ah VRLA batteries

Available Models

Standard

  • CFP702-4 C-Tec CFP Standard 2 Zone Conventional
  • CFP704-4 C-Tec CFP Standard 4 Zone Conventional
  • CFP708-4 C-Tec CFP Standard 8 Zone Conventiona

Economy

Unlike the Standard CFP fire panel, the economy version is NOT compatible with CFP repeaters, relay expansion boards or EN54-13 interface cards. It also has limited engineering functions.

  • CFP702E-4 C-Tec CFP Economy 2 Zone Conventional
  • CFP704E-4 C-Tec CFP Economy 4 Zone Conventional
  • CFP708E-4 C-Tec CFP Economy 8 Zone Conventiona

Downloads

  • Brochure (Adobe PDF)
  • Installation Manual (Adobe PDF)
  • User Manual (Adobe PDF)

Product Reviews

Free UK Delivery Over £150*

Secure Online Order Processing

Installation and User Guides

C Tec Cfp Fire Panel Installation Manual

Instructions and manuals are best downloaded from our individual product pages via the menu bar above. However, for your convenience, the main instructions for each of C-TEC's product ranges (typically our control panel manuals) can be downloaded via the menus below. 2002 saturn vue manual pdf. If you cannot find what you are looking for either here or on our product pages please contact our marketing team at marketing@c-tec.co.uk

CFP Economy Panel Installation Manual

Download

CFP Universal User Manual

Download

EP203 Extinguisher Panel Short Form Install Manual

Download

EP203 Extinguisher Panel Main Install Manual

Download

XFP 1 Loop 16 Zone Panel Engineering Manual

Download

XFP 1/2 Loop 32 Zone Panel Engineering Manual

Download

C Tec Cfp Fire Panel Manual

XFP Universal User Manual/Log Book

Download

ZFP Engineering Manual

Download

ZFP User Manual/Log Book

Download

PC Serial Comm Port setup for C-TEC Control Panels

Look them up with Everyi.com's. Apple iPod, iPhone & iPad Instruction Manuals (User Guides)Also see: As per reader requests, direct links to official Apple iPod, iPhone and iPad instruction manuals in PDF format - hosted by Apple's own - are provided below as well as on the specs page for each iPod, iPhone and iPad.Not sure which device or devices you need to locate? Apple ipod model a1320 user manual.

Download

Please visit our Power Supply product pages to download the instructions for this range of products.

SigTEL 4-64 Line Quick Start Install Guide

Download

SigTEL 4-64 Line Operator Instructions

Download

Please visit our Conventional Call System product pages to download the instructions for this range of products.

QT601/2 Quantec Controller Engineering Manual

Download

PC Serial Comm Port setup for C-TEC Control Panels

Fire Download

Please visit our Induction Loop System product pages to download the instructions for this range of products