Apc Smart Ups Sc 1000 User Manual

Posted on by
Advertising
  1. Apc Smart Ups Sc 1000 Service Manual
  2. Apc Back Ups Pro 1000 User Manual
  3. Apc Smart Ups Sc 1000 Manual
  4. Apc Smart Ups 1000 Manual
  5. Apc Smart Ups 1000 Software
  6. Apc Smart Ups 1000 Schematic

APC Smart-UPS SC 1000VA 230V - 2U Rackmount/Tower. APC Smart-UPS SC 1000VA 230V - 2U Rackmount/Tower. The Smart-UPS SC is an entry level UPS for low power network and point-of-sale (POS) equipment. Documentation CD, Rack Mounting Brackets, Smart UPS signalling RS-232 cable, USB cable, User Manual. View Product Overview. Smart-UPS 5000 VA 208/230 Vac Tower/Rack-Mount 5U User Manual 1 Introduction About this UPS The American Power Conversion (APC®) Uninterruptible Power Supply (UPS) provides protection for electronic equipment from utility power blackouts, brownouts, sags and surges. Summary of Contents of user manual for APC Smart-UPS 1500VA SUA1500RMJ2UB. Page 1User Manual English APC Smart-UPS® 750/1000/1500 VA 100/120/230 Vac 2U Rack-Mount Uninterruptible Power Supply 990-1194C 07/2008. Jun 04, 2018  I have just replaced the battery in my SC-1000 with a new RBC-33 from APC. The manual states i should execute a self test to clear the replace battery alarm. But the manual doesn't say how to execute a self test. There is no computer involved, so no powerchute.

7

English

Apc smart ups sc 1000 service manual

450 and 700 VA

Use the computer interface port for unit monitoring and control. See section 7.

The configuration button changes the unit’s sensitivity to utility voltage variations and the low
battery warning interval. See sections 5.9 and 5.10.

The configuration LED indicates the voltage sensitivity setting and the low battery warning
interval. See sections 5.9 and 5.10.

Apc Smart Ups Sc 1000 Service Manual

The site wiring fault indicator comes on when the unit is connected to an improperly wired AC
power outlet. See section 4.8.

The output circuit breakers (2200 VA and 3000 VA models only) trip when the connected loads
exceed the protected receptacle’s capacity. The center plunger of the circuit breakers extend when
tripped.

The Apple iPhone 4s was released in October 2011 and was one of the most popular phone from Apple. The phone had only 2G and 3G ability but for 2011 it was top of the line. Today there are other more updated options such as the Apple iPhone 6 Plus as well as the Apple iPhone 5s and 5c. Global Nav Open Menu Global Nav Close Menu; Apple; Shopping Bag. Free user manual for iphone 4s.

The input circuit breaker trips when loads exceed the unit’s capacity. The center plunger of the circuit
breaker extends when tripped. The paddle handle on 3000 VA model input circuit breaker shows “off ”
when tripped.

Use the transient voltage surge suppression (TVSS) ground connector for the ground leads of
telephone or network line protectors. See section 4.9.

The input power connector is a power cord with a NEMA 5-15P connector for 450 through 1400
VA models. See the table below for input power connectors on 2200 VA and 3000 VA models.

Schematic

Apc Back Ups Pro 1000 User Manual

The output power receptacles are NEMA 5-15R type. Optional output power receptacle kits are
available from the factory for the 2200 VA and 3000 VA models. See your dealer or call the
number at the front of this manual for more information.

Apc Smart Ups Sc 1000 Manual

Optional accessories can be installed in the accessory slot. See section 4.4 and section 7.

Apc Smart Ups 1000 Manual

Use the battery pack connector to connect the optional external battery pack (3000 VA model
only).

Advertising

Apc Smart Ups 1000 Software

This manual is related to the following products:

SMARTUPS Smart-UPS 1000, SMARTUPS Smart-UPS 1400, SMARTUPS Smart-UPS 3000

Apc Smart Ups 1000 Schematic