Agilent 4284a Lcr Meter User Manual
The Keysight (Agilent/HP) 4285A precision LCR meter provides a precise, reliable, high-speed solution for component and material measurement. For demanding RF component tests, the 4285A offers a higher test-frequency range, from 75 kHz to 30 MHz. Agilent 4285A Precision LCR Meter (Including Option 001, 002, 201, 202, 301) Maintenance Manual SERIAL NUMBERS This manual applies directly to instruments whose serial number prefix is 3009J-, and whose ROM-based firmware is version 01.00. For additional important information about serial numbers, read. The complete Agilent Technologies 4284A specifi-cations are listed in this data sheet. These specifi. BUS (GPIB), and manual Delay time Programmable delay from the trigger command to the start of the measurement, 0 to 60.000 s in 1 ms steps. Agilent 4284A Precision LCR Meter Data Sheet. Test Signal Frequency 20 Hz to 1 MHz, 8610.
The E4980A precision LCR meter provides the best combination of accuracy, speed, and versatility for a wide range of component measurements. Offering fast measurement speed and outstanding performance at both low and high impedance ranges, the E4980A is the ultimate tool for general R&D and manufacturing test of components and materials. User Manual 2009-02-10 Multifrequency C-V Measurements of Semiconductors (AN 369-5). Of passive component measurements in incoming inspection and R&D and shows the benefits of Keysight's Precision LCR Meter family; the 4284A and the 4285A 30 MHz LCR meters with digital Q capability. Application Note 2006-06-26.
C-V characteristics
sample—MOS diode
5
Adaptable
parameter testing
Discover new material properties
• High accuracy and precise
measurements
• Wide frequency ranges
• High test signal levels
• Agilent 16451B dielectric test fixture
The Agilent precision LCR meter family
provides the accuracy, resolution, high
test signal and bias levels
1
required for
material measurements. Using the
Agilent 16451B dielectric test fixture
provides you with accurate permittivity
and dissipation factor measurements.
The ability to output a constant test signal
level permits repeatable and accurate
magnetic/dielectric measurements. Both
the Agilent 4284A and Agilent 4285A offer
variable voltage and current test signal
level control.
Semiconductor testing
• Extend the test cable to the DUT
• Detect small parameter changes
• Rapidly acquire data
• Test at multiple frequencies
Both instruments allow you to extend the
front panel measurement port through test
cables, switches, and probers directly to
the DUT. The 6-digits of resolution give
you the ability to sense and identify
changes not normally seen by conventional
LCR meters.
The accuracies of the Agilent 4284A at
key test frequencies up to 1 MHz permit
complete DUT evaluation for either
production or laboratory needs.
For high speed device testing at frequen-
cies above 1 MHz, the best solution is the
Agilent 4285A.
A material’s
characteristics versus
frequency
1. Need Option 4284A/4285A-001
3
Satisfying your
performance needs
Adapt instrument configurations
to fit your test needs
• Internal voltage biasing up to ±40 Vdc
3
• High current biasing up to 40 A dc
3
(Agilent 4284A)
• Wide range of frequencies, 20 Hz to
30 MHz
So boys and Jan 17, 2017 People have been sharing their dubious life tricks in Reddit thread about 'unethical life hacks', and some of the tips are rather hair raising. Power acoustik pd 651b user manual. I could go to a website and copy straight what they have for highest win rate, but I didn't sub to this Reddit for nothing.
• BIN’ing and comparator functions for
handlers
• SMD, axial and radial test fixtures
3
Simplify your system
development and integration
• Programming language compatible
with IEEE 488.2
• Test port extensions: maximum 4 m
for 4284A
3
and 2 m for 4285A
• Identical operation for the entire
family of products
• Scanner, handler and GPIB interfaces
3
Key specifications
Agilent 4285A precision LCR meter
Test frequency
75 kHz to 30 MHz with 100 Hz resolution
Measurement range
1
Z , R, X :0.01 m
Ω to 99.9999 MΩ
Y , G,B :0.01 nS to 99.9999 S
C :0.01 fF to 999.999 µF
L :0.001 nH to 99.9999 H
D :0.000001 to 9.99999
Q :0.01 to 99999.9
Basic accuracy
Z , C and L:0.1% D:0.001
Test signal level range
Voltage
5 mVrms to 2 Vrms
Current
200 µArms to 20 mArms
Constant test signal level range
Voltage
10 mVrms to 1 Vrms
Current
100 µArms to 20 mArms
Hp 4284a Manual
Measurement time
2
30 ms/65 ms/200 ms
4285A with Option 4285A-001
Internal DC bias
± (1 mV ~ 40 V),
≤ 100 mA, 0.1% accuracy
4285A with Option 4285A-002, 42841A, and 42842C
DC current bias
0.01 A to 10 A
1. Refer to specifications for complete accuracy.
2. Supplimental information only.
3. The options, the accessories, or the test fixtures
are needed.